W1100 - CAVITY CLAY MASONRY
Structure and installation
ICANZ system reference for walls W1100 - Double brick wall with 50mm brick cavity with Polyweave, Double Sided Antiglare, Bubble foil or 10mm Reflective EPS board positioned mid-point of cavity (by use of spacers).
Note: cavity dimensions adjusted to compensate for reflective foil laminates having a thickness greater than 1mm
- Bright side of foil facing inwards.
- Non vented airspace or Bulk insulation installed in cavity.
- 10mm plasterboard lining.

NOTE: Total R-Values can be increased by substituting bulk insulation products of higher Material R-Value.

A. In accordance with AS/NZS 4859.1:2002. Amendment 1. 2006.
B. Temperatures and parameters are based on Australian climate assumptions. Air temperature difference 12oC (36oC less 24oC) for summer conditions and 6oC difference (18oC less 12oC) for winter.
C. Thermal resistance of air films and attic spaces based on values obtained from Section K5 and K6 of AS 4859.1:2006.
D. Building material elements based on 2000 AIRAH Handbook and attic thermal value based on AS4859.1 app K6 table K2.
E. Where reflective insulation is installed, a simple addition of R-values is not possible. Care must be taken to ensure the performance of reflective air spaces is not “double-counted”.
F. The emittance of the reflective surfaces are dependent on tested values and the conditions of the installation, as specified by AS/NZS 4859.1. Amendment 1. 2006.