R0900 Flat Metal Roof with no Ceiling (warehouse)
Structure
Flat metal roof at 0 to 5o pitch, with Rm2.5 foil faced blanket laid over safety mesh with a spacer installed directly under metal sheeting.

Installation
- Foil faced blanket insulation laid over safety mesh. Laps in foil should be 150mm, any tears or holes in the reflective foil should be repaired with foil tape. Where foil faced blanket is used, it should be allowed to recover to its nominal thickness by dishing the safety mesh or by providing a suitable spacer. Foil side of blanket should face into the air space below.
- Foil sarking only insulation laid over safety mesh. Laps in foil should be 150mm. Any tears or holes in the reflective foil should be repaired with foil tape. Bright side of foil to face into the air space downward.
- Tight safety mesh denotes no air space between reflective insulation and flat metal roof. Hence no contribution from an air space. Alternatively a spacer must be provided as per air space dimensions nominated.
NOTE: Total R-Values can be increased by substituting bulk insulation products of higher Material R-Value.